B. Connection for Power-- off-to-Unlock type:
-
+12V
LK - (GND)
LK+(COM)
+
N.O.
12V 300mA
EB+
EB -
Jumper set to 2-3 position
12
set to Normally Closed on the
3
Unlock Relay mode on DT software.
2. Additional power supply
DIPS
ON
1 2 3 4 5 6
DIPS-5: set to on,
unlocking time is 5 seconds.
When the electronic lock is over 12 Vdc, additional power supply for the lock is needed.
• The power supply for the lock must be less than 48Vdc 1.5A.
•
The Jumper must be removed when using additional power supply. The default is set for Power-to-Unlock
type(Normally open), if use Power-off-to-Unlock type, change the Unlock Relay mode to Normally closed on
the Parameter tab of DT CONFIG software.
• If different unlocking time is needed to be configured, please use the DT CONFIG software to change the setting
on the Parameter tab(see the program section).
C. Connection for Power-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+
-
+12V
DIPS
+
LK - (GND)
LK+(COM)
N.O.
1 2 3 4 5 6
-
EB+
EB -
Remove the Jumper
1
set to Normally Open on the
2
3
Unlock Relay mode.(default)
ON
DIPS-5: default set to off,
unlocking time is 1 second.
(In most cases, 1 second is
work for Power-to-Unlock type)
D. Connection for Power-- off-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+ -
+
-
Remove the Jumper
set to Normally Closed on the
+12V
DIPS
LK - (GND)
LK+(COM)
N.O.EB+
ON
1 2 3 4 5 6
EB -
DIPS-5: set to on,
1
unlocking time is 5 seconds.
2
3
Unlock Relay mode on DT software.
DT - System - Technical Guide 10